On Feb 12, 9:20pm, David Priebe wrote:
}
} A message from tq:
} pinuse a negative number; maybe tq/timetable needs higher totals
This message is wrong. First pinuse is percentage in use of
devices of a given class. That number can not be negative. This
message is triggered by pinuse being greater then 100. The second
error is that it's tq/classtable that would need updating, not
tq/timetable. One problem I've found on my system, is that if
somebody is logged off improperly (i.e. by somebody doing kill -9 on
all their processes), it can leave a stale utmp entry. This stale
entry messes up the totals. Anyways, there are a whole bunch of bugs
in tq (both portability and general). I have a large set of patches
for tq. I'm just waiting for the latest version of idled, which
somebody was supposed to look into getting me a couple of times.
}-- End of excerpt from David Priebe